110PPD @ 80°F/60%
3,600sq ft published max
40°Fminimum temp
Gravity draindrainage
Check price at Amazon ↗
Affiliate link. CrawlClimate may earn a commission if you purchase. Affiliate disclosure.
Capacity, normalized
Compare capacities under the same test condition
CrawlClimate uses the 80°F / 60% RH figure as the primary comparison value when the manufacturer publishes it. Saturation figures are kept separate because they are measured under much warmer, wetter conditions.
Comparable rating110 PPD80°F / 60% RH
Cooler-condition rating70 PPD65°F / 60% RH
Headline / saturationNot verifiedCompare with matching test conditions
Verified product data
Check against my crawl space →Specifications
Capacity @ 80°F / 60% RH110 PPD
Capacity @ 65°F / 60% RH70 PPD
Saturation / marketed maxNot verified
Published coverage3600 sq ft
Coverage contextManufacturer crawl-space coverage
Airflow370 CFM
Operating temperature40–95°F
DrainageGravity drain
DuctableYes
Automatic defrostYes
Wi-Fi / appNo
FilterMERV-13
Dimensions (W × H × D)14.4 × 24 × 29 in
Weight102 lb
Warranty6-year warranty