AprilAire · Product profile
E130
Specification researchLast verified: 2026-08-20
A specification-based product profile. Use the sizing calculator and the verified installation requirements below to decide whether it fits your crawl space.
130PPD @ 80°F/60%
4,000sq ft published max
50°Fminimum temp
Gravity draindrainage
View at manufacturer ↗
Normal manufacturer link. No commission is earned from this link.
Capacity, normalized
Compare capacities under the same test condition
CrawlClimate uses the 80°F / 60% RH figure as the primary comparison value when the manufacturer publishes it. Saturation figures are kept separate because they are measured under much warmer, wetter conditions.
Comparable rating130 PPD80°F / 60% RH
Cooler-condition ratingNot verified65°F / 60% RH
Headline / saturationNot verifiedCompare with matching test conditions
Verified product data
Check against my crawl space →Specifications
Capacity @ 80°F / 60% RH130 PPD
Capacity @ 65°F / 60% RHNot verified
Saturation / marketed maxNot verified
Published coverage4000 sq ft
Coverage contextSealed crawl-space sizing reference; manufacturer store also lists broader whole-house coverage
Airflow310 CFM
Operating temperature50–104°F
DrainageGravity drain
DuctableYes
Automatic defrostYes
Wi-Fi / appNo
FilterMERV 8
Dimensions19.5 × 18.8 × 30 in
WeightNot verified
WarrantyNot verified
Similar-capacity alternatives
Transparency
Sources & testing status
This page is currently labeled Specification research. The specifications come from published sources; any future CrawlClimate hands-on testing will be labeled separately.